P wave amplitude >2.5 mm in II and/or >1.5 mm in V1 (these criteria are not very specific or sensitive)
Better criteria can be derived from the QRS complex; these QRS changes are due to both the high incidence of RVH when RAE is present, and the RV displacement by an enlarged right atrium.
QR, Qr, qR, or qRs morphology in lead V1 (in absence of coronary heart disease)
QRS voltage in V1 is <5 mm and V2/V1 voltage ratio is >6 (Sensitivity = 50%; Specificity = 90%)